Posted tagged ‘primary’

HYDRAULIC HYBRID SYSTEM

August 23, 2011

01-hydraulic hybrid system-Hydraulic hybrid vehicles-HHV-hydraulic motors to power wheels-accumulators to store the pressurized  fluid nitrogen gas 

Introduction To Hydraulic Hybrid Vehicles:

Hybrid vehicles use two sources of power to drive the wheels. In a hydraulic hybrid vehicle (HHV) a regular internal combustion engine and a hydraulic motor are used to power the wheels.

Hydraulic hybrid systems consist of two key components:

  • High pressure hydraulic fluid vessels called accumulators, and
  • Hydraulic drive pump/motors.

Working of Hydraulic Hybrid Systems:

01-hydraulic-hybrid-retrofit-hydraulic hybrid system-HHS-regenerating braking energy

The accumulators are used to store pressurized fluid. Acting as a motor, the hydraulic drive uses the pressurized fluid (Above 3000 psi) to rotate the wheels. Acting as a pump, the hydraulic drive is used to re-pressurize hydraulic fluid by using the vehicle’s momentum, thereby converting kinetic energy into potential energy. This process of converting kinetic energy from momentum and storing it is called regenerative braking.

The hydraulic system offers great advantages for vehicles operating in stop and go conditions because the system can capture large amounts of energy when the brakes are applied.

The hydraulic components work in conjunction with the primary. Making up the main hydraulic components are two hydraulic accumulator vessels which store hydraulic fluid compressing inert nitrogen gas and one or more hydraulic pump/motor units.

The hydraulic hybrid system is made up of four components.

  • The working fluid
  • The reservoir
  • The pump or motor
  • The accumulator

The pump or motor installed in the system extracts kinetic energy during braking. This in turn pumps the working fluid from the reservoir to the accumulator, which eventually gets pressurized. The pressurized working fluid then provides energy to the pump or motor to power the vehicle when it accelerates. There are two types of hydraulic hybrid systems – the parallel hydraulic hybrid system and the series hydraulic hybrid system. In the parallel hydraulic hybrid, the pump is connected to the drive-shafts through a transmission box, while in series hydraulic hybrid, the pump is directly connected to the drive-shaft.

There are two types of HHVs:

  • Parallel and
  • Series.

Parallel Hydraulic Hybrid Vehicles:

01-hydraulic hybrid cars-HLA system-pump mode to motor mode-parallel hydraulic hybrid vehicles-nitrogen accumulator pressure 5000 psi

In parallel HHVs both the engine and the hydraulic drive system are mechanically coupled to the wheels. The hydraulic pump-motor is then integrated into the driveshaft or differential.

Series Hydraulic Hybrid vehicles:

01-hydraulic hybrid vehicles-combines regular internal combustion engine- hydraulic motor as a accumulator-kinetic energy into potential energy to drive the vehicle

Series HHVs rely entirely on hydraulic pressure to drive the wheels, which means the engine does not directly provide mechanical power to the wheels. In a series HHV configuration, an engine is attached to a hydraulic engine pump to provide additional fluid pressure to the drive pump/motor when needed.

Advantages:

  • Higher fuel efficiency.  (25-45 percent improvement in fuel economy)
  • Lower emissions.  (20 to 30 percent)
  • Reduced operating costs.
  • Better acceleration performance.

INDUCTIVE CHARGING

August 23, 2011

02-powermat-iphone-4-wireless-battery-charger-wireless charging mat-wireless receiver case-new wireless technology

In the future all electronic devices will be wirelessly powered. Small, battery-powered gadgets make powerful computing portable.

The battery charger should be capable of charging the most common battery types found in portable  devices today.  In addition, the charging  should be  controlled from the base station and a bidirectional communication system between  the pickups  and base  station  should be developed.


Inductive Power Systems:

Inductive Power Transfer (IPT)  refers to the concept of transferring electrical power between two isolated circuits across an air gap.  While based on the work and concepts developed by pioneers such as  Faraday and Ampere, it  is  only recently that IPT has been developed into working systems.

Essentially, an IPT system can be divided into two parts;

  • Primary and
  • Secondary.

The primary side of the system is made up of a resonant power supply and a coil. This power supply produces a high frequency sinusoidal current in the coil.  The secondary side (or ‘pickup’) has a smaller coil, and a converter to produce a DC voltage.

01-ecoupled wirelss charging technology-inductive coupling-keep battery life higher-concept-illustration

Working of Inductive Power Transfer:

In this system communications signals are encoded onto the waveform that provides power to the air gap. Communication from the primary side to the secondary is implemented by switching the power signal at the output of the resonant converter between its normal level  and a lower level which is detectable by the pickup but still provides enough power to control the pickup microcontroller. This process is called Amplitude Shift Keying (ASK). This is achieved by varying the output voltage of the buck converter which provides an input DC voltage to the resonant converter.

01-electric vehicles-charging-batteries-wireless charging of electric cars-Delphi_Witricity_Wireless

Communication from the secondary to the primary is achieved by a process called Load Shift Keying (LSK).  This involves varying the loading on the pickup.   Any load on the pickup will reflect a voltage on the primary circuit proportional to the load.  Therefore a variation in the load on the pickup can be detected by the charging station.

The communications system must provide two discrete levels of voltage reflected onto the primary side,  to represent the on and off states for digital communications. The difference must be easily detected on the primary side to provide a robust communications channel. Signals are decoded by simple filters and comparators which feed a  digital signal to the microcontrollers.

Advantages:

EV wireless charging parking 9-29

IPT has a number of advantages over other power transfer methods  – it is unaffected by dirt, dust, water, or chemicals.  In situations such as coal mining IPT prevents sparks and other hazards.  As the coupling is magnetic, there is no risk of electrocution even when used in high power systems.  This makes IPT very suitable for  transport  systems where vehicles follow a fixed track,  such as  in factory materials handling.